The exhaust gas temperature of modern gas furnaces and water heaters is much lower than past appliances because much more heat is harvested so you waste less money up your chimney.
Venting hot water heater and furnace through chimney.
That s a sign that hot gases are backdrafting toward the unit.
Traditional masonry chimneys were designed and sized to vent very hot flue gases from old coal wood burning or low efficiency gas furnaces.
Atmospheric venting refers to a system in which exhaust from the water heater naturally rises out of the appliance s combustion chamber then travels up through a standard chimney style flue that.
Refer to figure 2.
Before connecting a vent to a chimney make sure the chimney passageway is clear and free of obstructions.
The conditions explained in this post also apply to the wood burning appliances.
The duct may be metal or plastic depending on the type of vent system.
The area around the flue piping should be sealed where it enters the chimney.
When venting two appliances separately into a common chimney always install the smaller flue pipe appliance with lowest gph input at a higher point into the chimney than the larger flue pipe for the appliance with the largest gph input.
These should be tested as well especially if you see melted or melting plastic grommets on the side of the water heater.
Consequences of improperly assembled vent pipes problematic chimney flue deteriorating chimney walls can be sometimes fatal fire and carbon monoxide poisoning are topping the list.
Venting through existing chimney.
All water heater venting systems use a vent duct or pipe also called a chimney or flue to bring exhaust gases from the water heater to the outdoors.
Proper furnace water heater venting is an extremely important issue which depends on the performance of the house chimney chimney flue or other exhaust assemblies.
Illustration above an unused chimney flue or masonry enclosure may be used as a passageway for the installation of the water heater vent pipe.
A backdrafting water heater is arguably an even bigger problem than a backdrafting furnace.
Water heater ducts may lead directly outdoors or they may tie into a larger vent duct that also serves a gas or propane furnace or boiler in the home.
Two gas fired appliances such as a water heater and heating boiler may be vented into the same flue if your local jurisdiction approves of that installation.
In some locales fire officials also permit two gas appliances to vent into a single flue when the heaters are on different floors as we see in carson dunlop associates at reviewers sketch.