It cannot move air to a crawlspace or attic.
Venting bathroom into roof space.
In all cases the ducting needs to conduct the exchaust to the building exterior and needs to terminate in an animal proof vent cover.
On 2020 02 19 by mod joe the exhaust vent duct should not terminate in an attic or roof space.
This section notes that air exhausted from the bathroom must be sent outdoors not indoors to the same residence or indoors to any other dwelling unit.
Children seniors and people with weaken immune systems or respiratory issues are usually more susceptible to mold issues than others.
The 2nd bathroom vent drips on the floor and is ruining the ceiling.
To be properly terminated bathroom fans should exit the home through stem vents that are specifically used for this purpose.
Bathroom vent exhausting into attic space.
It needs to vent to the building exterior.
Recently we had a loft extension including a bathroom.
I was thinking of using a straight pvc pipe to create a horizontal run leading towards the roof and then somehow terminating it at the eaves although i don t know how to do this properly.
I understand this will be very bad for the wooden beams.
The master bathroom and the 2nd bathroom vent through the roof and through the same opening.
My home is like betty s.
Reducing the effectiveness of the insulation.
On 2020 02 19 by joe.
The 2 pipes one a 4 master and the other a 3 2nd do not go through the ceiling but into a common box that goes through the roof.
We have a bathroom with no external windows and an extractor fan that we just discovered vents straight upwards into the cold loft space.
Took the fan off and lo and behold no ducting.
Until recently builders and plumbers might have got away with it as long as the.
Now winter is here we ve noticed the ceiling extractor blows a cold gale in when the wind comes from the west so i decided to find the vent outlet.
After further inspection it was evident the current home owners vented their bathroom exhaust fans directly into the open attic space and not to the outside.
These stem vents should be properly connected to the bathroom ducts to ensure that moisture is traveling to the exterior not the attic space.
When we got into the attic i quickly noticed the smell moisture and what i could see as mold on the roof rafters above each bathroom.
Venting moist air into an attic or crawl space can result in damp or wet insulation.
What is the irc code referencing this.
A venting a shower or bathroom extractor fan into the roof space is a crazy thing to do but surprisingly common.
Bathroom ventilation fan duct routing routing a bath vent duct down out or up through an attic or roof out.
Is it okay to vent a ceiling fan into the attic for just a toilet room.